This document describes which configuration settings need to be made on a LANCOM device in order to use the monitoring and notification function when operating with a LANCOM Battery Pack.
Requirements: Procedure: 1) Connect the LANCOM router or LANCOM access point to the LANCOM Battery Pack.
2) Open the configuration for the LANCOM device in LANconfig and switch to the menu item Log & trace → General → Battery pack.
3) Enable the
Monitor battery pack option. By default, notifications about events are sent via e-mail, SNMP, and syslog.
- Notification by e-mail only works if you previously make the required settings in the menu Log & trace → SMTP account.
- If you wish to customize the notifications, you can do this by using the Notifications button.
4) Go to the menu
COM ports → Devices → Device mode and add a new entry to the list:
- Set the Device type to Outband
- Set the Device mode to UPS.
5) Now write the configuration back to the LANCOM device.