Page tree
Skip to end of metadata
Go to start of metadata


Description:

This document describes the connection parameters for establishing a configuration / CLI connection via the serial interface of a LANCOM device.


Procedure:

Establish a connection between the LANCOM device and the configuration computer via the serial configuration cable.

Start a terminal program on the configuration computer, e.g. PuTTY (download). Use the following connection parameters:
    LANCOM Router & Access-Points:

    Baudrate: 115200
    Stop Bits: 1
    Data Bits: 8
    Parity: N
    Flow control: RST/CTS


    LANCOM Switches:

    Baudrate: 115200
    Stop Bits: 1
    Data Bits: 8
    Parity: N
    Flow control: none

    LANCOM Unified Firewalls:

    Baudrate: 9600
    Stop Bits: 1
    Data Bits: 8
    Parity: N
    Flow control: none