Description: This document describes the connection parameters for establishing a configuration / CLI connection via the serial interface of a LANCOM device. Procedure: Establish a connection between the LANCOM device and the configuration computer via the serial configuration cable. Start a terminal program on the configuration computer, e.g. PuTTY (download). Use the following connection parameters:
LANCOM Router & Access-Points:
Baudrate: 115200
Stop Bits: 1
Data Bits: 8
Parity: N
Flow control: RST/CTS
LANCOM Switches:
Baudrate: 115200
Stop Bits: 1
Data Bits: 8
Parity: N
Flow control: none
LANCOM Unified Firewalls:
Baudrate: 9600
Stop Bits: 1
Data Bits: 8
Parity: N
Flow control: none
|
|