This document describes which configuration settings need to be made on a L=
ANCOM device in order to use the monitoring and notification function when =
operating with a LANCOM Battery Pack.
Requirements:
Procedure:
1) Connect the LANCOM router or LANCOM access point to the LANCOM Battery P=
ack.
2) Open the configuration for the LANCOM device in LANconfig and switch to =
the menu item Log & trace =E2=86=92 General =E2=86=92 Batt=
ery pack.
3) Enable the
Monitor battery pack option. By default=
, notifications about events are sent via e-mail, SNMP, and syslog.
- Notification by e-mail only works if you previously make the required s=
ettings in the menu Log & trace =E2=86=92 SMTP account=
.
- If you wish to customize the notifications, you can do=
this by using the Notifications button.
4) Go to the menu
COM ports =E2=86=92 Devices =E2=86=92 Device=
mode and add a new entry to the list:
- Set the Device type to Outband
- Set the Device mode to UPS.